EPA 608: Lessons & Preparation Route

Short lessons, worked examples, and practice that connects.

01
Core

Certification and appliance boundaries

Classify the appliance before selecting a certification. Type I, II and III have different equipment scopes.

9 min + practice17 questions
02
Core

Venting, recovery and ownership

Recovered refrigerant may be returned to equipment under the same ownership; transfer to another owner requires reclamation by an EPA-certified reclaimer.

9 min + practice17 questions
03
Core

Evidence and certification records

Technicians keep certification evidence at the business through three years after ceasing technician operations; EPA does not generally require carrying the card at every service call.

9 min + practice16 questions
04
Type I

Recognizing small appliances

A small appliance is fully manufactured, charged and hermetically sealed in a factory with five pounds or less of refrigerant. Both the construction definition and charge condition matter; small-looking equipment alone does not qualify.

9 min + practice16 questions
05
Type I

Small-appliance recovery decisions

The small-appliance percentage target is 80% with pre-November-15-1993 recovery equipment or a nonfunctional compressor; 90% applies with later equipment and a functional compressor.

9 min + practice17 questions
06
Type I

Following the disposal chain

The final person in the disposal chain must ensure refrigerant recovery before final disposal; a documented prior recovery can satisfy the chain requirement.

9 min + practice17 questions
07
Type II

High- and medium-pressure evacuation

Select pressure category, the less-than-200 versus at-least-200 full-charge row, then the recovery-equipment date column.

9 min + practice17 questions
08
Type II

ODS leak-repair triggers

For Section 608 ODS leak repair, a full charge of at least 50 lb and an annual leak rate exceeding the applicable category trigger are relevant; category triggers are 10%,20%,30%.

9 min + practice17 questions
09
Type II

Service exceptions and oil

The limited exception for a non-major repair not followed by evacuation to the environment requires high- or very-high-pressure equipment to reach 0 psig before opening.

9 min + practice16 questions
10
Type III

Low-pressure evacuation and units

EPA lists 25 mm Hg absolute for the general low-pressure appliance evacuation target, in both recovery-equipment date columns.

9 min + practice17 questions
11
Type III

Low-pressure repair planning

For the limited non-major low-pressure repair exception not followed by evacuation to the environment, pressurize to 0 psig before opening; prohibited subsequent-purge methods are not generally allowed.

9 min + practice17 questions
12
Type III

Chiller records and lifecycle decisions

For covered large ODS appliances, the customer receives refrigerant-added records and required inspection/verification documentation with dates, methods, locations andresults.

9 min + practice16 questions

Selected Core, Type I, Type II and Type III written-knowledge foundations; not complete official examination coverage.